A thatched roof is beautiful, cool in summer and very South African. It is also the roof type most at risk from fire. A thatch fire retardant treats the thatch so that it is harder to set alight and slower to burn, which can buy precious time if a spark, a nearby fire or a lightning strike reaches the roof.
This guide explains what a fire retardant for thatch does and what it cannot do, why it does not replace a lightning conductor, how the two work together, and what insurers usually look for on a thatched property. It also covers Thatch Marshal 8000, the water-based fire retardant StopSurge applies to thatch roofs, and simple habits that make a thatched home, lodge or lapa safer.
Why thatch roofs are a fire risk
Dry thatch is a natural fuel. Once it catches, flames can spread across a roof quickly, and a fire that starts high up in the thatch is hard to reach and put out. Common ways a thatch roof catches fire include:
- Lightning: a strike on or near an unprotected thatched building can ignite the roof directly.
- Sparks: from a chimney, fireplace or braai too close to the roof line.
- Nearby fires: veld fires, burning rubbish or a neighbour’s fire carried by the wind.
- Electrical faults: poor wiring or fittings in or near the roof space.
Much of South Africa has a high number of lightning strikes during the summer storm season, and thatch is common on homes, game lodges, wedding venues and lapas. That combination is why thatch owners think carefully about both lightning and fire.
What a thatch fire retardant does
A thatch fire retardant does not make thatch fireproof. What it does is change how the thatch behaves when it meets a flame or spark. A treated roof is harder to ignite, and once alight, fire spreads more slowly across it. That can make the difference between a small, contained burn and a roof that is lost in minutes, and it gives people more time to get out and to fight the fire.
A good thatch fire retardant should be designed for thatch, so it treats the reed or grass without harming it. It should also suit the look of the roof, because most owners chose thatch for its appearance.
Thatch Marshal 8000: the fire retardant we apply
For thatched roofs, StopSurge applies Thatch Marshal 8000, a water-based fire retardant designed specifically for thatch. It:
- reduces flame spread
- improves fire safety
- enhances the look of your thatch roof
We can apply Thatch Marshal 8000 on its own or as part of a lightning protection project on a thatched building. When you request a quote, tell us the size of the roof and when it was last thatched or treated, and we will advise on the application. We recommend reapplying it every five years.
Thatch fire retardant vs lightning conductor
The two are often confused, but they do different jobs:
| Thatch fire retardant | Lightning conductor | |
|---|---|---|
| What it does | Makes thatch harder to ignite and slows the spread of fire | Gives lightning a safe path to earth, away from the building |
| What it protects against | Fire from any source, including sparks and nearby fires | A lightning strike on the structure |
| What it cannot do | Stop a strike or make thatch fireproof | Stop fires from sparks, braais or electrical faults |
| Testing and certification | Applied to the thatch | Installed, SABS-tested and certified for insurance |
A thatch fire retardant does not replace a lightning conductor. On a thatched building, a strike carries a huge amount of energy, and only a properly designed and earthed lightning protection system can carry that energy safely to ground. The retardant then adds a second layer: if a fire does start, from any cause, it is slower to take hold.
Why thatch needs both
For most thatched buildings, a lightning protection system is the first priority, and a thatch fire retardant is the second layer of protection. On thatch, the usual approach is a free-standing lightning mast beside the building rather than conductors on the roof itself, so the strike is kept away from the thatch. Our guide to thatch roof lightning protection explains how a system for a thatched building normally works, and our lightning protection guide compares masts and mesh systems.
StopSurge installs lightning protection using SABS and SANS approved materials, in line with SABS and SANS codes of standards, including SANS 10313 and the SANS 62305 series. We then SABS-test the system so it can be certified. Our lightning protection rod guide explains the parts of a system and why earthing matters.
Thatch, fire retardant and your insurance
Insurers take thatch seriously, and many ask for a lightning protection certificate before they will cover a thatched property, or when a policy is renewed. StopSurge is insurance approved. We install, test and certify new lightning protection systems, and we test and certify existing systems for insurance, so you have the certificate your insurer is looking for.
Insurers’ requirements for a thatch fire retardant differ, so ask yours what they need for your policy. If they ask about a fire retardant as well as a lightning certificate, mention both when you request a quote, and we will plan the work together.
When to treat, and when to treat again
A thatch fire retardant treats the thatch it is applied to. That means new thatch, a re-thatched roof or a large repair is untreated until it has its own application. Weather and time also wear on any roof treatment, so we recommend that you reapply Thatch Marshal 8000 every five years. Keep a record of when your roof was treated, so you know when the next application is due.
Lightning protection needs regular attention too. Annual servicing is recommended, because the resistance of the earthing can change over time and conductors can be damaged. Have the system inspected after re-thatching, roof alterations or extensions, because building work can disturb conductors and earth connections.
Other ways to make a thatched building safer
A thatch fire retardant works best alongside good habits:
- Keep braais, fire pits and outdoor fires well away from the roof line.
- Have chimneys and fireplaces checked and maintained.
- Cut back overhanging trees and clear dry vegetation around the building.
- Keep a fire extinguisher or hose within easy reach.
- Have electrical work in or near the roof space done by a qualified electrician.
Surge protection devices on your electrical installation are also worth discussing with an electrician. StopSurge does not install surge protection devices: a qualified electrician fits those. Our work is the lightning protection system and its testing and certification.
Get a free quote for your thatched building
StopSurge has been in lightning protection since 2009 and works on homes, lodges, venues and businesses nationwide. Quotations are free. Contact us, or call or WhatsApp 068 637 5918, and tell us:
- the type of building and the size of the thatched roof
- whether you need a new lightning protection system, or testing and certification of an existing one
- whether you would like a Thatch Marshal 8000 application
- the address or area of the property
- whether your insurer has asked for a lightning protection certificate
You can see examples of thatch installations on our Our Work page, and our guide to the lightning protection price explains what affects the cost of a quote.
Frequently asked questions about thatch fire retardant
What does a thatch fire retardant do?
A thatch fire retardant makes thatch harder to ignite and slows the spread of fire across the roof. It does not make thatch fireproof, but it can buy time to get people out and fight a fire. StopSurge applies Thatch Marshal 8000, a water-based fire retardant designed specifically for thatch.
Does a fire retardant replace a lightning conductor on a thatch roof?
No. A fire retardant slows fire, but it cannot stop a lightning strike. Only a properly designed and earthed lightning protection system carries a strike safely to ground. Thatched buildings are best protected with both.
Do insurers require lightning protection on thatched houses?
Many insurers ask for a lightning protection certificate for thatched properties. StopSurge is insurance approved, and we install, SABS-test and certify new systems, and test and certify existing systems for insurance. Ask your insurer what they need for fire retardant, as requirements differ.
Does new thatch need to be treated?
Yes. A fire retardant treats the thatch it is applied to, so new thatch, a re-thatched roof or a large repair is untreated until it has its own application. After that, reapply Thatch Marshal 8000 every five years.
How often should thatch fire retardant be reapplied?
We recommend reapplying Thatch Marshal 8000 every five years, because weather and time wear on any roof treatment. New thatch, a re-thatched roof or a large repair needs its own application first. Keep a record of when your roof was treated, so you know when the next application is due.
Does StopSurge install surge protection?
No. StopSurge installs, tests and certifies lightning protection systems and applies Thatch Marshal 8000 to thatch. Surge protection devices are fitted by a qualified electrician.